General information

With the heating control application from digitalSTROM you can easily set your home heating according to your wishes. With a few clicks you can configure the behavior in the individual rooms, set the desired temperatures for the different temperature modes and plan your time profiles for the room based night setback function. digitalSTROM automatically adjusts each room to the temperatures that you want.

The first step is to install the blue digitalSTROM terminal blocks and the temperature sensor (e.g. digitalSTROM sensor iSENS200). A selction of radio-based EnOcean devices are also supported.

Using the digitalSTROM Climate Control app for smartphones, you can read actual temperatures and change the setpoint temperatures, as well as define, configure and control many other functions.

Preconditions

  1. The digitalSTROM server must be updated to the software version 1.9.
  2. Temperature sensors have to be installed and assigned to the appropriate rooms using the digitalSTROM configurator.
  3. The heating actuators (control valves) are installed and assigned to the appropriate rooms. In addition, the kind of installed heating system ( radiators or underfloor heating) has to be defined in the device properties dialog.
  4. Its recommended to install the my.digitalSTROM server App for remote access to the full heating functionality.
  5. The heating system has to be hydraulic balanced, so that the system is set to the optimal flow of hot water. This is usually done by the heating installer during commissioning.

Operation

The digitalSTROM heating application provides an infrastructure that intelligently controls individual rooms using connected room temperature sensors and actuators (heating control valves). The sensors and actuators have to be assigned to a room and regulated at room level. Target temperatures can be set and selected for different modes of operation.

• During normal operation you can comfortably choose between the Comfort and Eco modes.

To save energy, you can:

You can use either the app Climate Control on your smartphone or this app to set the desired temperature for the five operating modes: Comfort, Eco, Cool, Night and Vacation.

In order to maximise energy savings, digitalSTROM heating always chooses the lowest possible temperature. For example, if a room was manually set to unused (mode Cool) and 19°, and the night setback mode is set to 20 degrees, the system will keep the unused mode Cool active during the night setback period.

‚Overview’ Tab

The actual status of your heating can be seen at a glance in Overview.

You can choose between Comfort and Eco modes in the Mode in normal operation in Apartment. The chosen mode is always active, unless you have chosen the night setback or the unused modes, or if you are on vacation.

The actual temperature, the target temperature and the actual mode of the rooms are displayed in Rooms. If needed, you can switch on or off the unused mode (Cool) in individual rooms.

Please note: General information and error messages are displayed in Messages and Events.

‚General Settings’ Tab

You can configure the following parameters under General Settings:

The operation mode of your rooms, as well as their sensors and actors are displayed in Room settings.

You can choose between the following operation modes (double-click the selected room):

  1. Off – no controller active: The room is not regulated, and all heating valves are closed. If there is a sensor in the room, the actual temperature will still be shown in the smartphone app Climate Control. Please also see the Notes below!
  2. Radiator: The room has a temperature sensor, as well as at least one heater/radiator with a heating actuator. You can choose a target temperature for each operating mode.
  3. Underfloor: The room has a temperature sensor, as well as underfloor or panel heating. You can choose a target temperature for each operating mode.
  4. The setting value follows a reference room: The room has at least one heating actuator but doesn’t have any temperature sensor. In this operating mode, the heating valve control value follows the value of a neighbouring room (reference room). For this purpose, a reference room must be chosen, and an offset value can be optionally defined. Example: if the room should only be fed with half the amount of warm water, just define an offset value of -50%. The offset ranges from -100% (meaning that the room is not heated) to +300%, which means that the room receives 4 times more warm water than the reference room. No standard temperature for the operations modes can be defined for a room with this setting.
  5. Use predefined settings values: In case there is neither a temperature sensor nor a reference room available, you can define a fixed heating valve value for each operating mode. For instance, you can decide to have the heating valves fully open when you are in the apartment and fully closed during the night or when you are absent.
  6. Automatic: with this option, the connected device will be automatically identified. PLease note that you need to define the connected device in the Hardware tab under device properties. This mode is the standard configuration for your heating installation.

For the operating modes 2 to 4, you can additionally define a heating valve value for the emergency operation. Example: in case the temperature sensor stops responding in a room and the regulation stops, the heating will continue operating in emergency mode and the value you have defined will be applied to the heating valve. This means that the room will continue to be heated, although it will not be regulated by temperature.

‚Standard temperatures and setting values’

You can define here the standard temperatures in Celsius degrees for all rooms and for the 5 operating modes (Comfort, Eco, Cool, Night and Vacation). If the chosen room is in the operation mode Use predefined setting values, then you can choose a valve value instead of a temperature.

These settings can also easily be configured in the smartphone app Climate Control under Standard Temperatures.

‚Time profiles’ Tab

You can define here time profiles for night setbacks and unused periods, for which the temperature will be automatically lowered in order to actively save energy.

Configure night setback: with this option, you can reduce the temperature of your entire home (mode night).

Configure room setback: with this option, you can reduce the temperature of individual rooms. For example, if you use a room only during the weekend, you can reduce the temperature during weekdays (mode Cool).

If you have defined time profiles for the night setback and for the Room setback, the room will always be set to the lowest temperature.

The nigh and room setbacks can be defined for every day or for the whole week. These time profiles can also be adjusted in the smartphone app Climate Control.

Your time profiles will be displayed with bars in the graphical interface.

Notes: